CentOS下下查看硬盘型号、大小等信息(含Raid)
一、普通模式(该机硬盘没有做磁盘阵列)
1、fdisk -l 查看你的硬盘编号,如sda,sdb 等
2、smartctl --all /dev/sda
- smartctl --all /dev/sda #该命令centos自带
- [root@localhost ~]# smartctl --all /dev/sda
- smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-504.el6.x86_64] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Device Model: SanDisk SD6SB1M128G1022I
- Serial Number: 141218410909
- LU WWN Device Id: 5 001b44 becdaed9d
- Firmware Version: X231600
- User Capacity: 128,035,676,160 bytes [128 GB]
- Sector Size: 512 bytes logical/physical
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 6
- Local Time is: Fri Jan 16 08:35:48 2015 CST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
从上面可以看出,硬盘型号为SanDisk SD6SB1M128G1022I,容量为128GB
二、磁盘阵列 RAID模式
如果该机有做磁盘阵列,那么运行上述命令会报错,得不到你要的磁盘信息。可以借助MegaCli命令
MegaCli命令系统不自带,需要额外下载,
下载地址:
http://www.lsi.com/downloads/Public/RAID%20Controllers/RAID%20Controllers%20Common%20Files/8.07.14_MegaCLI.zip
下载之后解压,
unzip CSA1.5-MegaCli_REL80571.zip
cd MegaCLI/MegaCli_Linux
rpm -ivh MegaCli-8.05.71-1.noarch.rpm
安装完成
ln -s /opt/MegaRAID/MegaCli/MegaCli64 /usr/bin/
默认安装在/opt下面,建立软链到/usr/bin
- [root@localhost bin]# /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -aALL
- Adapter #0
- Enclosure Device ID: 32
- Slot Number: 0
- Drive's position: DiskGroup: 0, Span: 0, Arm: 0
- Enclosure position: 1
- Device Id: 0
- WWN: 50000C0F02E57BE9
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SAS
- Raw Size: 279.396 GB [0x22ecb25c Sectors]
- Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
- Coerced Size: 278.875 GB [0x22dc0000 Sectors]
- Sector Size: 0
- Firmware state: Online, Spun Up
- Device Firmware Level: D1S6
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x50000c0f02e57bea
- SAS Address(1): 0x0
- Connected Port Number: 0(path0)
- Inquiry Data: WD WD3001BKHG D1S6WX11E83NU249
- FDE Capable: Not Capable
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature :31C (87.80 F)
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Port-1 :
- Port status: Active
- Port's Linkspeed: Unknown
- Drive has flagged a S.M.A.R.T alert : No
- Enclosure Device ID: 32
- Slot Number: 1
- Drive's position: DiskGroup: 0, Span: 0, Arm: 1
- Enclosure position: 1
- Device Id: 1
- WWN: 50000C0F028F32ED
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SAS
- Raw Size: 279.396 GB [0x22ecb25c Sectors]
- Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
- Coerced Size: 278.875 GB [0x22dc0000 Sectors]
- Sector Size: 0
- Firmware state: Online, Spun Up
- Device Firmware Level: D1S6
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x50000c0f028f32ee
- SAS Address(1): 0x0
- Connected Port Number: 1(path0)
- Inquiry Data: WD WD3001BKHG D1S6WX11E83VD242
- FDE Capable: Not Capable
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature :31C (87.80 F)
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Port-1 :
- Port status: Active
- Port's Linkspeed: Unknown
- Drive has flagged a S.M.A.R.T alert : No
- Enclosure Device ID: 32
- Slot Number: 2
- Drive's position: DiskGroup: 0, Span: 0, Arm: 2
- Enclosure position: 1
- Device Id: 2
- WWN: 50000C0F02E5B8ED
- Sequence Number: 2
- Media Error Count: 0
- Other Error Count: 0
- Predictive Failure Count: 0
- Last Predictive Failure Event Seq Number: 0
- PD Type: SAS
- Raw Size: 279.396 GB [0x22ecb25c Sectors]
- Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
- Coerced Size: 278.875 GB [0x22dc0000 Sectors]
- Sector Size: 0
- Firmware state: Online, Spun Up
- Device Firmware Level: D1S6
- Shield Counter: 0
- Successful diagnostics completion on : N/A
- SAS Address(0): 0x50000c0f02e5b8ee
- SAS Address(1): 0x0
- Connected Port Number: 2(path0)
- Inquiry Data: WD WD3001BKHG D1S6WX11E83NU081
- FDE Capable: Not Capable
- FDE Enable: Disable
- Secured: Unsecured
- Locked: Unlocked
- Needs EKM Attention: No
- Foreign State: None
- Device Speed: 6.0Gb/s
- Link Speed: 6.0Gb/s
- Media Type: Hard Disk Device
- Drive Temperature :28C (82.40 F)
- PI Eligibility: No
- Drive is formatted for PI information: No
- PI: No PI
- Port-0 :
- Port status: Active
- Port's Linkspeed: 6.0Gb/s
- Port-1 :
- Port status: Active
- Port's Linkspeed: Unknown
- Drive has flagged a S.M.A.R.T alert : No
- Exit Code: 0x00
从上面可以看出,该机有三块硬盘,型号为,
WD WD3001BKHG D1S6WX11E83NU249,容量为300GB。
MegaCli常用参数介绍
MegaCli -adpCount 【显示适配器个数】
MegaCli -AdpGetTime –aALL 【显示适配器时间】
MegaCli -AdpAllInfo -aAll 【显示所有适配器信息】
MegaCli -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】
MegaCli -PDList -aAll 【显示所有的物理信息】
MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】
MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】
MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】
MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】
MegaCli -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】
MegaCli -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】
磁带状态的变化,从拔盘,到插盘的过程中。
Device |Normal|Damage|Rebuild|Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online
最新文章
- css如何实现水平居中呢?css实现水平居中的方法?
- U3D 动画帧事件问题
- 安装crab
- 【原】iOSCoreAnimation动画系列教程(一):CABasicAnimation【包会】
- IIS是如何处理ASP.NET请求的
- Html4与Html5的关键区别
- 本地存储(cookie&;sessionStorage&;localStorage)
- CentOS 6.4 安装 thrift-0.9.3
- Android设计模式(1)----单例模式
- [Effective C++ --022]将成员变量声明为private
- 学习笔记_第一个strut程序_之中文乱码,过滤器解决方案及过程总结
- Carthage&;&;cocopads 摘抄笔记
- OC基础16:复制对象
- hdu 4119 Isabella's Message
- java做单用户的多重并发会话数限制
- java HotSpot 内存管理白皮书
- JAVA之旅(十五)——多线程的生产者和消费者,停止线程,守护线程,线程的优先级,setPriority设置优先级,yield临时停止
- bzoj3693: 圆桌会议 二分图 hall定理
- 【tp5】tp5实现空模块、空控制器、空操作的页面404跳转
- 巧用CurrentThread.Name来统一标识日志记录(完结篇)